The TrackFulleco converter subscribes to a signal announcing full economy mode, and adds full economy programmed current to a CycleData.
Trigger
Buffered
- CycleData from CalculateCorrection.
rda3://UCAP-NODE-SPS-HYSTCOMP-TEST/SPS.MBI.FULLECO/IREFFull economy , which normally does not change, since FULLECO stays at the initial reference current, normally 155 A for MBIs.
Trigger:
XTIM.SX.FCY-MMODE-CT/AcquisitionTiming signal announcing full economy 1150ms before cycle start.
Logic
If the MMODE trigger is received, the buffered CycleData will have its current_prog field updated with the full economy programmed current, economy_mode field updated, and then emitted.
Output
onNewCycleDataAvailable