Supercycle
Logged in SPS MD logbook: https://logbook.cern.ch/elogbook-server/GET/showEventInLogbook/4049443
The flat top of the MD2 was completely flat. We increased the last point of the flat top by 10 G and let the conversation algorithm move it back to the original current, which seem to work.

The trim noise seems to be around 2E-6T, which is fine for flat top.
Problems
Documented in ~/cernbox/hysteresis/dipole/notebooks/BC2024/SFTPRO_mini.ipynb
We found inconsistencies of measurements of the field by 3 G at flat top on MD2, which seems to have been caused by AWAKE cycle preeceeding it
Which for some reason has some value also logged as complete zeros. This weird behaviour is corrected by the MD1 marker after MD2.
According to Vincenzo this is a glitch that may be caused by marker jitter, but not something that we can get around easily. For the values that are completely zero, this might be a glitch in NXCALS, however I find that extremely unlikely.